9,339
Data centers
18.13 GW
Reported · 622 data centers
313.14 GW
Pipeline MW
318.86 TWh
Est. energy / yr
111.2 Mt
Est. CO₂ / yr
154
Countries

expand_lessStatus

Operational8,222
Under construction343
Planned / permitted677
Cancelled / closed97
hollow = approximate location
my_location
fit_screen
layers

ecoData center energy & CO₂

Reported values (site pages, operator reports) are used first; everything else is a modelled estimate: IT MW × 0.6 load × 8760 h × PUE, CO₂ = energy × the country’s grid intensity, water = IT energy × WUE. Treat estimates as orders of magnitude.

boltEst. energy / yr
318.86 TWh
cloudEst. CO₂ location-based
111.2 Mt
energy_program_savingEst. CO₂ market-based
60.05 Mt
water_dropEst. water / yr
93.74 M m³
speedData centers with site PUE
112
heatHeat-reuse data centers
64
verifiedISO 50001 data centers
165
electric_meterGrid gCO₂/kWh, weighted
358

speedMost efficient — reported site PUE

Data centerPUECapacity
Blönduós Campus
Borealis Data Center · IS
1.03—
Google Data Center Fredericia
Google · DK
1.06—
Meta Luleå Data Center
Meta · SE
1.07—
Google Datacenter Eemshaven
Google · NL
1.07—
Google Data Center · Quilicura
Google · CL
1.08—
Google Dublin Data Center
Google · IE
1.08—
Google · Hamina
Google · FI
1.09—
Start Campus SIN01
Start Campus · PT
1.138 MW
Supercalcolatore Leonardo - Rete EuroHPC
CINECA · IT
1.110 MW
Google 印西データセンター · 印西市
Google · JP
1.1—
Rechenzentrum Ostermiething
STACKIT (Schwarz Group) · AT
1.1—
Google Midlothian Data Center
Google · US
1.11—
Google: Lok Yang 1
Google · SG
1.12—
Google Red Oak Campus
Google · US
1.14—
AirTrunk MEL1
AirTrunk · AU
1.15185 MW
AirTrunk SYD1
AirTrunk · AU
1.15130 MW
AirTrunk SYD2 Sydney North
AirTrunk · AU
1.15120 MW
AirTrunk TOK2 Tokyo West
AirTrunk · JP
1.1560 MW
Colt London North Data Centre
Colt · GB
1.1535 MW
MERLIN Edged BIL03 - Bilbao-Arasur
MERLIN Edged · ES
1.1522 MW
DCstar Datacenter Burcht DCB
DCStar NV · BE
1.150.5 MW
DXC Wynyard Data Center
HPE · GB
1.16—
OPCORE - DC5 / PAR5
OPCORE (Scaleway/iliad) · FR
1.18—
Meta Singapore Data Center
Meta · SG
1.19150 MW
Global Switch London East
Global Switch · GB
1.287 MW
NEXTDC S3
NEXTDC · AU
1.280 MW
Vantage Data Centers (QC4)
Vantage Data Centers · CA
1.250 MW
Kao Data KLON-01
Kao Data · GB
1.235 MW
NTT London 1 Data Center (LON1)
NTT DATA Global Data Centers · GB
1.232 MW
GDC Tallinn DC-1
MCF Group Estonia OU · EE
1.232 MW
Colt Paris South West (Les Ulis)
Colt · FR
1.224 MW
Gravity Edge LDN1
Gravity Edge · GB
1.215 MW
VIRTUS LONDON2 (Hayes)
VIRTUS Data Centres · GB
1.212 MW
Glesys Stockholm 1
Glesys AB · SE
1.21 MW
atNorth FIN02
atNorth · FI
1.2—
atNorth DEN01
atNorth · DK
1.2—
EcoDataCenter Falun
EcoDataCenter · SE
1.2—
atNorth ICE03
atNorth · IS
1.2—
KPN DC2
KPN Wholesale · NL
1.2—
atNorth ICE01
atNorth · IS
1.2—

cloudLargest estimated emitters

location-based
Data centerCO₂/yrMarketGrid
Switch Citadel Campus
Switch (Switch Inc.) · US
1.86 Mt0 t384
Equinix DC1 - Ashburn
Equinix · US
1.38 Mt55.3 kt384
Amazon Project Rainier
Amazon Web Services · US
1.36 Mt0 t384
Meta Huntsville Data Center Campus
Meta · US
1.06 Mt0 t384
Meta Prineville Data Center Campus
Meta · US
871.4 kt0 t384
NEXTDC M3
NEXTDC · AU
844.9 kt844.9 kt554
Meta Altoona Data Center Campus
Meta · US
762.5 kt0 t384
Switch CITADEL Campus
Switch (Switch Inc.) · US
716.1 kt0 t384
Google The Dalles Data Center Campus
Google · US
659.6 kt0 t384
Meta Gallatin Data Center Campus
Meta · US
653.6 kt0 t384
Switch Pyramid Campus
Switch (Switch Inc.) · US
644.5 kt0 t384
AirTrunk MEL1
AirTrunk · AU
619.3 kt173.4 kt554
xAI Macrohard Colossus 2
xAI · US
601.5 kt601.5 kt384
EdgeCore Mesa Data Center Campus
EdgeCore Digital Infrastructure · US
590.1 kt590.1 kt384
Galaxy Helios Data Center Campus
Galaxy Data Centers · US
572.9 kt572.9 kt384
Lancium Clean Campus (Crusoe / Stargate Site 1)
Crusoe · US
572.9 kt572.9 kt384
Cyquator - Vashi Datacenter
Cyquator Technologies · IN
523.6 kt523.6 kt705
Novva West Jordan Campus
Novva Data Centers · US
501.3 kt501.3 kt384
RACK59 Data Center · Oklahoma City
RACK59 Partners, LLC · US
501.3 kt501.3 kt384
CyrusOne Chandler (PHX1-PHX8)
CyrusOne · US
497.7 kt110.5 kt384
Meta Singapore Data Center
Meta · SG
467.9 kt0 t499
MY06
Bridge Data Centres · MY
448.1 kt448.1 kt600
AirTrunk SYD1
AirTrunk · AU
435.2 kt121.9 kt554
xAI Colossus
xAI · US
429.7 kt429.7 kt384
CtrlS Chennai DC1
CtrlS · IN
423.1 kt422.2 kt705

heatHeat reuse

district heating, greenhouses, pools…
Data centerCapacityWaste heat (est)
CDG1
CloudHQ, LLC · FR
74 MW555.3 GWh
Vantage Data Center (FRA1)
Vantage Data Centers · DE
56 MW294.3 GWh
Vantage Zurich I (ZRH1)
Vantage Data Centers · CH
40 MW298.5 GWh
NTT London 1 Data Center (LON1)
NTT DATA Global Data Centers · GB
32 MW168.2 GWh
NTT Berlin 2 Data Center (BER2)
NTT DATA Global Data Centers · DE
24 MW126.1 GWh
Digital Realty VIE1 - Vienna
Digital Realty · AT
21 MW111.4 GWh
CSC – IT Center for Science
CSC · FI
8 MW1.21 TWh
nLighten Sophia Antipolis NCE1
nLighten · FR
6 MW31.5 GWh
nLighten Paris PAR1
nLighten · FR
2.4 MW12.6 GWh
nLighten Besancon MLH1
nLighten · FR
1.2 MW6.3 GWh
Glesys Stockholm 1
Glesys AB · SE
1 MW5.3 GWh
31173 DC Lund Mobilvägen
31173 Services AB · SE
0.5 MW3.7 GWh
Meta Odense Data Center
Meta · DK
—527.2 GWh
Digital Realty Stockholm STO1
Digital Realty · SE
—116.2 GWh
Google Datacentre Waltham Cross
Google · GB
—146.3 GWh
Apple data center (Viborg)
Apple · DK
—192.8 GWh
Meta Luleå Data Center
Meta · SE
—438.1 GWh
Google · Hamina
Google · FI
—120.4 GWh
Korbank Data Center · Wroclaw
Korbank S. A. · PL
—20.6 GWh
PLUTEX DC01
PLUTEX GmbH · DE
—154.3 GWh
nLighten Dusseldorf DUS1
nLighten · DE
—16.8 GWh
Google Farciennes Data Center
Google · BE
——
Equinix PA3 - Paris, Saint-Denis
Equinix · FR
—136.4 GWh
CPH07
Microsoft · DK
—97.1 GWh
ICE Datacenter
RISE · SE
—120.4 GWh
nLighten Munich MUC1
nLighten · DE
—29 GWh
Equinix HE4 - Helsinki, Hansa
Equinix · FI
—25.8 GWh
Google Data Center Fredericia
Google · DK
—221.6 GWh
CPH01
Microsoft · DK
—51.7 GWh
Equinix FR4 - Frankfurt, West
Equinix · DE
—98.8 GWh
Vaultica Data Centers | OSL02
Vaultica Data Centers - NORDICS · NO
—60.7 GWh
nLighten Swindon BRS2
nLighten · GB
—18.4 GWh
LuxConnect DC2 - Bissen
LuxConnect S.A. · LU
—79.2 GWh
Equinix AM6 - Amsterdam, Duivendrechtsekade
Equinix · NL
—69.7 GWh
EcoDataCenter Falun
EcoDataCenter · SE
—350.4 GWh
Digital Realty Paris PAR8
Digital Realty · FR
—125.5 GWh
nLighten Leipzig LEJ1
nLighten · DE
—9.8 GWh
Vantage Berlin I (BER11)
Vantage Data Centers · DE
—298.8 GWh
Equinix TR5 - Toronto
Equinix · CA
—9.7 GWh
Equinix AM5 - Amsterdam, Schepenbergweg
Equinix · NL
—69.7 GWh
Equinix FR8 - Frankfurt, West
Equinix · DE
—25.3 GWh
nLighten Berlin BER1
nLighten · DE
—45.2 GWh
nLighten Chester
nLighten · GB
—23.7 GWh
Equinix OT1 - Ottawa
Equinix · CA
—23.1 GWh
Equinix FR6 - Frankfurt, West
Equinix · DE
—22 GWh
nLighten Nottingham EMA1
nLighten · GB
—101.6 GWh
nLighten Cologne CGN1
nLighten · DE
—22.8 GWh
nLighten Bristol BRS1
nLighten · GB
—23.7 GWh
nLighten Milton Keynes LTN1
nLighten · GB
—5.8 GWh
nLighten Hamburg HAM1
nLighten · DE
—6.4 GWh
Hetzner – Rechenzentrumspark Falkenstein
Hetzner Online · DE
—27.3 GWh
Equinix PA10 - Paris, Saint-Denis
Equinix · FR
—67.1 GWh
Equinix HE3 - Helsinki, Suvilahti
Equinix · FI
—14.2 GWh
nLighten Amsterdam AMS2
nLighten · NL
—55.8 GWh
Switch Datacenters AMS4
Switch Datacenters (NL) · NL
—72.6 GWh
nLighten Hanover HAJ1
nLighten · DE
—10 GWh
nLighten Leeds LBA1
nLighten · GB
—7.6 GWh
Equinix HE5 - Helsinki, Viikinmäki
Equinix · FI
—12.8 GWh
Equinix AM7 - Amsterdam, Kuiperberweg
Equinix · NL
—95.8 GWh
nLighten Geneva GVA1
nLighten · CH
—65 GWh

energy_program_savingCleanest operators

est. location-based gCO₂e per kWh of their data centers (≥ 50 GWh/yr)